10.1 Important Notes
Only professional personnel with extensive knowledge in the fields of electrical engineering
and drive technology are allowed to test and set up the drive.
DANGER
Lethal Voltage!
There is a danger of serious personal injury or death by electrical shock.
Lethal danger exists at live parts of the device.
Built-in protection measures such as insulation or shielding may not be
removed.
Work on the electrical installation may only be performed by trained
and qualified personnel, in compliance with the regulations for safety at
work, and only with switched off mains supply, and secured against
restart.
WARNING
Automatic Restart!
Risk of death or serious injury for humans working in the machine. The
drive might restart automatically after power on, voltage dip or interruption
of the supply voltage, depending on the parameter setting. If parameter
DRV.ENDEFAULT is set to 1,
then place a warning sign ("WARNING: Possible Automatic Restart" or
similar) to the machine.
Ensure, that power on is not possible, while humans are in a dan-
gerous zone of the machine.
CAUTION
High Temperatur!
Risk of minor burns. The heat sink of the drive can reach temperatures up
to 80°C in operation.
Check the heat sink temperature before handling the drive.
Wait until the heat sink has cooled down to 40°C before touching it.
If the drive has been stored for more than 1 year, you must re-form the capacitors in the DC
bus link circuit. Re-forming procedures are described in the Kollmorgen Developer Network
(Forming).
Additional information on setting up the equipment:
Programming parameters and control loop behavior are described in the online help of the
setup software.
The setup of any fieldbus is described in the corresponding manual on the DVD.
AKD Installation | 10 Setup
Kollmorgen | kdn.kollmorgen.com | October 2017 185

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals