EasyManuals Logo

Kollmorgen AKD series Installation Manual

Kollmorgen AKD series
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #209 background imageLoading...
Page #209 background image
10.4.3.2 Errors
When an Error or Alarm occurs, always check the controller log messages. The log mes-
sages will provide more details about the failure and the history of events leading up to the fail-
ure. From the log messages, you can determine the specifics about the cause of the failure to
correct the underlying problem.
Eliminate errors and faults in compliance with work safety rules. Troubleshooting only by
qualified and trained staff.
More information about error and alarm messages, causes, remedy and clearing errors can
be found in the WorkBench online help and in KDN.
Error Description
E01 Critical temperature exceeded. Operation is stopped, CPU will be put to sleep.
E02 Out of memory. KAS runtime is stopping.
E03 Fan failure.
E10 Firmware is corrupted.
E11 Flash is corrupted, no filesystem is available.
E12 Not enough flash memory available.
E13 Out of NVRAM space for retained variables.
E14 Reset to Factory Defaults failed.
E15 Cannot read/write files from/to a SD card.
E16 Not enough space available on the SD card.
E20 Runtime plug-in, process, thread or application failed to start.
E21 Runtime plug-in, process, or thread failed to respond during operation.
E22 Fatal error in PLC program, application stopped.
E23 CPUis overloaded.
E24 PLC application cannot be started
E30 EtherCAT communication failure during operational mode.
E31 EtherCAT communication failure during preop mode.
E32 EtherCAT communication failure during bootstrap mode.
E33 EtherCAT failed to initialize into operational mode.
E34 EtherCAT failed to initialize into preop mode.
E35 EtherCAT failed to initialize into bootstrap mode.
E36
EtherCAT network discovery failed.
E37 EtherCAT failed to return to init state.
E50 Backup to SD card failed.
E51 Restore from SD card failed..
E52 SD Backup files are missing or corrupt.
E53 SD Backup files are not compatible.
AKD Installation | 10 Setup
Kollmorgen | kdn.kollmorgen.com | October 2017 209

Table of Contents

Other manuals for Kollmorgen AKD series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen AKD series and is the answer not in the manual?

Kollmorgen AKD series Specifications

General IconGeneral
Continuous CurrentUp to 180 A
Control ModesPosition, Velocity, Torque
Communication InterfacesEtherCAT, CANopen, Modbus TCP/IP
Feedback OptionsResolver, Encoder
Safety FeaturesSafe Torque Off (STO), Safe Stop 1 (SS1)
Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overtemperature
Switching Frequency8 kHz, 16 kHz
Ambient Temperature0°C to 40°C
Operating Temperature0 - 40 °C (derating may apply)
Humidity5% to 95% non-condensing

Related product manuals