M A E D A Mini-Crawler Crane Section 5 – STORAGE
1/2019 MC285C-3 5-71
STORAGE
Temporary Storage
If the machine is in need of repair and is
temporarily waiting for service, use the following
guidelines to notify all applicable personnel the
machine is not to be used.
Place DO NOT OPERATE warning tags on the
crane operation levers and visible areas of the
machine.
Record information such as failure description,
name and contact information of the storage
manager, and the estimated storage time.
Remove the engine key and keep in a safe place.
Place blocks at the rubber tracks to keep the
machine from moving.
Fig. 5-161
Long-Term Storage
This section describes only the long-term storage
methods that are not defined in standard
specifications.
Use the following procedure for storing the
machine for 6 months or longer (3 months or
longer if stored in hot or humid environment).
Before Storage
Place the machine in the travelling position during
long-term storage to protect the cylinder rods.
(Cylinder rod corrosion prevention) See
“TRAVELLING POSITION” on page 4-24.
Fig. 5-162
When storing the machine for long periods, follow
these procedures:
• Wash and clean each section of the machine
and store inside. If the machine is to be stored
outside, select a flat location where the machine
will not be exposed to water, flooding or other
elements.
• Fill the fuel tank with fuel, lubricate all grease
fittings and change the engine oil.
• Disconnect the positive (+) and negative (-)
battery terminals and cover the battery or
remove the battery from the machine.
• Fill the engine cooling system with coolant fluid
and check or adjust the mixture as necessary to
prevent freezing.
• Cover the machine. In addition, cover the
electric motor and hydraulic pump of the electric
unit with a plastic sheet. Use a dehumidifying
agent in the covered sheet to keep the machine
free of moisture.
During Storage
WARNING! Exhaust Hazard. Operate the
machine in a well-ventilated area.
Operate the machine once a month (5 minutes
minimum) during storage to prevent corrosion
buildup and to charge the battery.
Quarterly insulation resistance tests of electric
motor wiring are required during long-term
storage. Contact us or our sales service agency to
request inspection procedures and service
information.