Manitowoc Published 09-09-16, Control # 229-09 3-39
MLC650 SERVICE/MAINTENANCE MANUAL ELECTRICAL SYSTEM
Table 3-14. IOSB22 Test Voltages
Pin I/O Network Function Voltages
PB1-1 GND Ground (from ground stud on rotating bed)
0V
DC
PB1-2 KL15 Control Module Ignition Power (from relay K6)
0V
DC
Open, 24 V
DC
Closed
PB1-3 ID01 Not Used—For Possible Future Expansion
0V
DC
PB1-4 ID02 Not Used—For Possible Future Expansion
0V
DC
PB1-5 OPH6A01 Right Rear Carbody Jack Raise Solenoid
0V
DC
Off, 24 V
DC
On
PB1-6 OPH6A02 Right Rear Carbody Jack Lower Solenoid
0V
DC
Off, 24 V
DC
On
PB1-7 OPH6A03 Left Front and Rear Travel Motors Control
0V
DC
Off, 24 V
DC
On
PB1-8 OPH6A04 Right Front and Rear Travel Motors Control
0V
DC
Off, 24 V
DC
On
PB1-9 IMID1 Module Identifier Input (from ground stud on rotating bed)
0V
DC
PB1-10 CAN1-H CAN Bus B—High No Connection
PB1-11
+U
B
Supply Power for Control Module Outputs
24 V
DC
PB1-12
+U
E
Control Module Battery Power
24 V
DC
PB1-13 ID03 Not Used—For Possible Future Expansion
0V
DC
PB1-14 ID04 Not Used—For Possible Future Expansion
0V
DC
PB1-15 ID05 Not Used—For Possible Future Expansion
0V
DC
PB1-16 No Connection
PB1-17 No Connection
PB1-18 No Connection
PB1-19 CAN1_L CAN Bus B—Low Not Applicable
PB1-20
+U
B
Supply Power for Control Module Outputs
24 V
DC
PB1-21 No Connection
PB1-22 No Connection
PB1-23 No Connection
PB1-24 No Connection
PB1-25 No Connection
PB1-26 No Connection
PB1-27 No Connection
PB1-28 No Connection
PB1-29 IMID3 Module Identifier Input (from ground stud on rotating bed)
0V
DC