ACCESSORIES MLC650 SERVICE/MAINTENANCE MANUAL
10-66
Published 09-09-16, Control # 229-09
VPC-MAX On Hook Limit Switch Adjustment
The VPC-MAX on hook limit switches require adjustment.
On Hook Switch Adjustment
See Figure 10-53 for the following.
1. Set the adjustable limit switch arm to 56 mm (2 in).
2. Set the switch to trip when the beam hook is 6 mm (0.24
in) away from contacting the pin on the rear of the
rotating bed.
3. The free state of the adjustable arm (4) is 60°, and the
tripped state of the arm is 34°.
Item Description
1 Beam Up Limit Switch
2 VPC-MAX Beam
3 Rotating Bed
4 On Hook Limit Switch Adjustable Arm
5 Switch Mount Bracket
6 On Hook Limit Switch
7 56 mm
FIGURE 10-53