ELECTRICAL SYSTEM MLC650 SERVICE/MAINTENANCE MANUAL
3-34
Published 09-09-16, Control # 229-09
PC1-29 GND Ground (from ground stud on rotating bed)
0V
DC
PC1-30 CAN1_L CAN Bus C—Low Not Applicable
PC1-31 CAN1_H CAN Bus C—High Not Applicable
PC1-32 No Connection
PC1-33 No Connection
PC1-34 IMID2
Module Identifier Input (from ground stud on rotating
bed)
0V
DC
PC1-35 IDF02 Drum 1 Left Motor Speed Sensor
55 to 85% of Input Voltage Over Tooth
2 to 10% of Input Voltage Over Gap
PC1-36 IDF07 Drum 5 Motor Speed Sensor
55 to 85% of Input Voltage Over Tooth
2 to 10% of Input Voltage Over Gap
PC1-37 IDF08 Drum 5 Motor Speed Sensor
55 to 85% of Input Voltage Over Tooth
2 to 10% of Input Voltage Over Gap
PC1-38 IACV15 Fixed Mast Connected
0V
DC
Not Installed, 24 V
DC
Installed
PC1-39 IACV13 Rotating Bed Level Sensor
5.025 V
DC
@ 0°
±1.005 V
DC
Offset/°
PC1-40 IACV12 Rotating Bed Level Sensor
5.025V
DC
@ 0°
±1.005V
DC
Offset/°
PC1-41 OS85H
8.5 V
DC
Power to Drums 3 and 5 Motor Speed Sensors 8.5 V
DC
PC1-42 OPH3A26 Drum 2 Right Motor Control
0V
DC
Open, 24 V
DC
Closed
PC2-1 PGND1 Ground (from rotating bed ground stud)
0V
DC
PC2-2 ODH3A03 Drums 1 and 2 / 6 Camera Lights
0V
DC
Off, 24 V
DC
On
PC2-3 ODH3A09 Drum 6 Right Brake Release Solenoid
0V
DC
Off, 24 V
DC
On
PC2-4 ODH3A08 Drum 6 Pawls Out Solenoid
0V
DC
Off, 24 V
DC
On
PC2-5 ODH3A05
Power Bus:
Drum 6 Minimum Bail Normally Closed Limit Switch
Drum 6 Pawl Normally Open Limit Switch
24 V
DC
PC2-6 ODH3A13 Drum 5 Pawls Out Solenoid
0V
DC
Off, 24 V
DC
On
PC2-7 ODH3A15
Power Bus:
Ambient Air Temperature Sensor
Engine Fuel Level Sensor
Maximum Boom Angle Limit Switch
Mast Strap Load Pin
Live Mast Angle Sensor
24 V
DC
PC2-8 No Connection
PC2-9 No Connection
PC2-10 PGND2 Ground (from ground stud on rotating bed)
0V
DC
PC2-11
+U
B
SW1
Battery Power for Control Module Outputs
24 V
DC
Pin I/O Network Function Voltages