NICE3000
new
User Manual
7 Function Code Table
- 179 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
F7-06 Overload function
0: Disabled
1: Enabled
0 -
224
F7-07 Limit switch forbidden
0: No
1: Yes
0 -
224
F7-08
Time interval of
random running
0–1000 0 s
224
Group F8: Enhanced function parameters
F8-00
Load for load cell
auto-tuning
0–100 0 %
225
F8-01 Pre-torque selection
0: Pre-torque invalid
1: Load cell pre-torque
compensation
2: Automatic pre-torque
compensation
0 -
225
F8-02 Pre-torque offset 0.0–100.0 50.0 %
225
F8-03 Drive gain 0.00–2.00 0.60 -
226
F8-04 Brake gain 0.00–2.00 0.60 -
226
F8-05 Current car load 0–1023 0 -
225
F8-06 Car no-load load 0–1023 0 -
225
F8-07 Car full-load load 0–1023 100 -
225
F8-08 Anti-nuisance function
0: Anti-nuisance function disabled
1: Nuisance judged by load cell
2: Nuisance judged by light
curtain
4: Nuisance judged by light-load
signal
0 -
226
F8-09
Emergency
evacuation operation
speed at power failure
0.000 to F3-11 0.050 m/s
193, 219
F8-10
Emergency
evacuation operation
mode at power failure
0: Motor not running
1: UPS
2: 48 V battery power supply
0 -
219
F8-11 Brake apply delay 0.200–1.500 0.600s s
201
F8-12
Fire emergency oor
2
0 to F6-00 0 -
221
F8-14
HCB communication
rate
Bit0 = 0: HCB communication
baud rate 9600 bps
Bit0 = 1: HCB communication
baud rate 38400 bps
Bit4: Energy saving of HCB
communication
0 -
227