EasyManua.ls Logo

Monarch nice3000 - Page 186

Monarch nice3000
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NICE3000
new
User Manual
7 Function Code Table
- 185 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
FC-62
Latest fault month and
day
0–1231 0 MM.DD
248
FC-63
Latest fault hour and
minute
0–23.59 0 HH.MM
248
FC-64
Logic information of
latest fault
0–65535 0 -
248
FC-65
Curve information of
latest fault
0–65535 0 -
248
FC-66
Set speed upon latest
fault
0.000–4.000 0 m/s
248
FC-67
Feedback speed upon
latest fault
0.000–4.000 0 m/s
248
FC-68
Bus voltage upon
latest fault
0.0–999.9 0 v
248
FC-69
Current position upon
latest fault
0.0–300.0 0 m
248
FC-70
Output current upon
latest fault
0–999.9 0 A
248
FC-71
Output frequency
upon latest fault
0.00–99.99 0 Hz
248
FC-72
Torque current upon
latest fault
0.0–999.9 0 A
248
Group Fd: Communication parameters
Fd-00 Baud rate
0: 9600
1: 38400
0 bit/s
249
Fd-02 Local address
0–127
0: Broadcast address
1 -
249
Fd-03
Communication
response delay
0–20 10 ms
249
Fd-04
Communication
timeout
0.0–60.0 0.0 s
249
Fd-05 Re-leveling stop delay 0.00–2.00 0.00 s
249
Fd-07 HCB:JP1 input
0: Reserved
1: Elevator lock signal
2: Fire emergency signal
3: Present oor forbidden
4: VIP oor signal
5: Security oor signal
6 Door close button signal
7: Second re emergency oor
signal
1 -
223
Fd-08 HCB:JP2 input 2 -
223

Table of Contents