NICE3000
new
User Manual
7 Function Code Table
- 185 -
Function
Code
Parameter Name Setting Range Default Unit Property Page
FC-62
Latest fault month and
day
0–1231 0 MM.DD
●
248
FC-63
Latest fault hour and
minute
0–23.59 0 HH.MM
●
248
FC-64
Logic information of
latest fault
0–65535 0 -
●
248
FC-65
Curve information of
latest fault
0–65535 0 -
●
248
FC-66
Set speed upon latest
fault
0.000–4.000 0 m/s
●
248
FC-67
Feedback speed upon
latest fault
0.000–4.000 0 m/s
●
248
FC-68
Bus voltage upon
latest fault
0.0–999.9 0 v
●
248
FC-69
Current position upon
latest fault
0.0–300.0 0 m
●
248
FC-70
Output current upon
latest fault
0–999.9 0 A
●
248
FC-71
Output frequency
upon latest fault
0.00–99.99 0 Hz
●
248
FC-72
Torque current upon
latest fault
0.0–999.9 0 A
●
248
Group Fd: Communication parameters
Fd-00 Baud rate
0: 9600
1: 38400
0 bit/s
★
249
Fd-02 Local address
0–127
0: Broadcast address
1 -
★
249
Fd-03
Communication
response delay
0–20 10 ms
★
249
Fd-04
Communication
timeout
0.0–60.0 0.0 s
★
249
Fd-05 Re-leveling stop delay 0.00–2.00 0.00 s
★
249
Fd-07 HCB:JP1 input
0: Reserved
1: Elevator lock signal
2: Fire emergency signal
3: Present oor forbidden
4: VIP oor signal
5: Security oor signal
6 Door close button signal
7: Second re emergency oor
signal
1 -
★
223
Fd-08 HCB:JP2 input 2 -
★
223