7 Function Code Table NICE3000
new
User Manual
- 188 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
FE-32
Elevator function
selection 1
Bit2: Re-leveling function
Bit3: Door pre-open function
Bit4: Stuck hall call cancellation
Bit5: Night security oor function
Bit6: Down collective selective
peak service
Bit7: Parallel/Group control peak
service
Bit8: Time-based service oor
function
Bit9: VIP function
Bit11: Car call deletion
Bit12: Hall call deletion
34816 -
262
FE-33
Elevator function
selection 2
Bit1: Door open holding at open
limit
Bit2: Door close command not
output upon door close limit
Bit4: Auto reset for RUN and
brake contactor stuck
Bit5: Slow-down switch stuck
detection
Bit7: Forced door close
Bit8: NO/NC output selection of
shorting motor stator contactor
Bit9: Immediate stop upon re-
leveling
Bit13: High-speed elevator
protection function
Bit15: Opposite door independent
control
36 -
263
Group Fr: Leveling adjustment parameters
Fr-00
Leveling adjustment
function
0: Disabled
1: Enabled
0 -
252
Fr-01
Leveling adjustment
record 1
00000–60060
30030 mm
252
Fr-02
Leveling adjustment
record 2
30030 mm
252
Fr-20
Leveling adjustment
record 20
30030 mm
252
Group FF: Factory parameters
Group FP: User parameters
FP-00 User password 0–65535 0 -
254