8 Description of Function Codes NICE3000
new
User Manual
- 262 -
Bit Function Description Default
Bit1 Reserved - 0
Bit2
Decelerating to stop at
valid light curtain
During normal-speed running, the elevator decelerates to stop
immediately after the light curtain acts, and then runs to the registered
destination oor after the light curtain restores. This function is mainly
used in the case of manual door.
0
Bit9
Mode without door
open/close limit
In this mode, the door open/close limit signal is not required, and
the system automatically judges door open/close limit. The system
determines that door open limit is implemented 3s after the door open
command is output and door close limit is implemented 3s after the
door close command is output.
0
Bit10 Light-load input Input signal 24/56 is used for light-load input. 0
â—†
â—†
FC-01 Program Control 2 for Protection Function
Function Code Parameter Name Setting Range Default Unit Property
FC-01
Program control 2 for protection function 0–65535 65 -
★
FC-01 is used to set program control related to protection functions. Each bit of the function code denes a
function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of FC-01 are described in the following table.
Bit Function Description Default
Bit0 Overload protection It sets whether to implement overload protection. 1
Bit1
Canceling protection at
output phase loss
It sets whether to implement protection at output phase
loss.
0
Bit4
Light curtain judgment at
door close limit
At door close limit, the door re-opens if the light curtain is
valid.
0
Bit5
Canceling SPI
communication judgment
It sets whether to implement wire-breaking detection
on SPI communication between the MCB and the drive
board.
0
Bit6 to Bit8 Reserved - 0
Bit14
Canceling protection at input
phase loss
It sets whether to implement protection at input phase
loss.
0
â—†
FE-32 Elevator Function Selection
Function Code Parameter Name Setting Range Default Unit Property
FE-32
Elevator function selection 0–65535 34816 -
☆
FE-32 is used to select the elevator functions. Each bit of the function code denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of FE-32 are described in the following table.