NICE3000
new
User Manual 8 Description of Function Codes
- 261 -
8
â—†
F6-42 Program Control Selection 3
Function Code Parameter Name Setting Range Default Unit Property
F6-42
Program control selection 3 0–65535 0 -
★
F6-42 is used to select program control functions. Each bit of the function code denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of F6-42 are described in the following table.
Bit Function Description Default
Bit0 Reserved - 0
Bit1
Cancelling door open/close
command at delay after door
open/close limit
Bit1 = 1: The door open/close command is cancelled at
the delay of 1s after door open/close limit.
0
Bit2
Not judging door lock state at
door close output
On normal conditions, the system determines that the
door is completely closed only when the door close limit
signal is active and the door lock is applied.
If this function is enabled, the system need not judge the
door lock state.
0
Bit3
Door close command output
during running
The door close command is output continuously during
the elevator running.
0
Bit4
Returning to base oor for
verication at rst-time power-on
The elevator runs to the bottom oor for verication at
power-on for the rst time.
0
Bit5
Clearing calls immediately at
elevator lock
Bit5 = 1: After the elevator lock signal becomes active, the
elevator clears all car calls and hall calls and lands at the
elevator base oor.
Bit5 = 0: After the elevator lock signal becomes active, the
elevator clears hall calls and responds to all registered
car calls, and then lands at the elevator base oor.
0
â—†
â—†
FC-00 Program Control for Protection Function
Function Code Parameter Name Setting Range Default Unit Property
FC-00
Program control for protection function 0–65535 0 -
★
FC-00 is used to set program control related to protection functions. Each bit of the function code denes a
function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the function is disabled.
For details on how to view and set this function code, see the descriptions in section 8.21.1.
The functions dened by the binary bits of FC-00 are described in the following table.
Bit Function Description Default
Bit0
Short circuit to ground
detection at power-on
Whether the motor is short circuited to ground is detected at power-on.
If the motor is short circuited to ground, the controller blocks the output
immediately, and reports the fault.
0