NICE3000
new
User Manual Preface
- 7 -
Function Description Remarks
Interference degree
judgment
The system judges the degree of communication interference. Viewed in FA-24
Earthquake protection
When the earthquake detection device acts and inputs a signal
to the system, the elevator lands at the nearest oor and stops
running. After the earthquake signal becomes inactive and the
fault is reset manually, the elevator restores to normal running.
-
Current cancellation in
ramp mode
For the PMSM, after the elevator decelerates to stop, the
holding current of the motor is cancelled in ramp mode,
preventing abnormal noise during current cancellation.
-
Independent working
power supply
The NICE3000
new
system supports not only three-phase 380
VAC but also single-phase 220 VAC to meet different applications
of the power supply system (such as 220 V UPS)
-
Automatic voltage
identication
The system detects the bus voltage and automatically adjusts
the running speed of the elevator to adapt to the situation of
insufcient power from power supply (such as emergency UPS).
-
Parallel/Group Control and Other Functions
Parallel control
The system supports parallel control of two elevators and
provides multiple scheduling algorithms to meet requirements of
different customers.
Refer to section 6.2.3
Dispersed waiting
In parallel/group control, the elevators can wait at different
oors.
Set in F6-09
Parallel/Group control
exit
If the parallel/group control exit switch of a certain elevator in
a parallel/group control system is valid or the time for exiting
the parallel/group control is reached, the elevator exits parallel/
group control and runs independently. This does not affect
normal running of the parallel/group control system.
-
Parallel/Group control
automatic exit
If an elevator in the parallel/group control system cannot
respond to calls in time due to faults, the elevator automatically
exits the parallel/group control system and runs independently.
This does not affect normal running of the parallel/group control
system.
-
Anti-nuisance function
The system automatically judges the number of passengers in
the car and compares it with the number of registered car calls.
If there are excessive car calls, the system determines that it
is nuisance and cancels all car calls. In this case, passengers
need to register correct car calls again.
F8-08 (Anti-nuisance
function)
Prompt of non-door
zone stop
The system gives a prompt when the elevator stops at a non-
door zone area due to faults.
-
Full-load indication
When the elevator is full-loaded, a full-load indication is
displayed on the HCBs and the elevator directly runs to the
desired oors.
-
Interface for
intelligent residential
management
The system provides an interface for intelligent residential
management to perform remote monitoring on the state of
elevators in the residential district.
Residential
monitoring board
MCTC-MIB required
Parameter copy
You can upload and download parameters by using the
operation panel MDKE6.
MDKE6 operation
panel required
Energy-saving Functions
Car energy-saving
If there is no running command within the set time, the system
automatically cuts off the power supply to the lamp and fan in
the car.
F9-01 (Time for
fan and lamp to be
turned off)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Monarch nice3000 and is the answer not in the manual?

Monarch nice3000 Specifications

General IconGeneral
Control MethodSensorless vector control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overload, short circuit, overheating
Operating Temperature-10°C to +40°C
Storage Temperature-20°C to 60°C