Preface NICE3000
new
User Manual
- 8 -
Function Description Remarks
Energy-saving running
with standby power
supply
When the normal power supply is interrupted and the emergency
power supply is used, the system reduces the running speed
of the elevator in the prerequisite of guaranteeing the smooth
running curve.
-
Arrival gong disabled
at night
Within the set time period, the arrival gong is disabled. -
Energy-saving of idle
door machine
After the car lamp is turned off, the system does not output the
door close command, which reduces power consumption of the
door machine.
-
2. Optional functions
Function Description Remarks
Door pre-open
During normal stop, when the elevator speed is smaller than 0.2
m/s and the door zone signal is active, the system shorts the
door lock by means of the shorting door lock circuit contactor and
outputs the door open signal, implementing door pre-open. This
improves the elevator use efciency.
MCTC-SCB required
Micro-leveling
After landing at a oor, the elevator may move upward or
downward due to the load change and the car door is not aligned
with the ground, which is inconvenient for in and out of passengers
and goods. In this case, the system allows the elevator to run to
the leveling position in the door open state at the leveling speed.
MCTC-SCB required
Power failure
emergency
evacuation
For the elevator congured with standby power supply, the system
uses the standby power supply to implement low-speed self-rescue
in the case of power failure.
Standby power
supply required
Onsite
commissioning
The system can control and monitor running of elevators by using
the NEMS software.
NEMS software
required
Commissioning
by cell phone
The Android cell phone can be connected to the controller through
the external Bluetooth module, and you can commission and
monitor the elevator, and upload and download parameters by
using the cell phone.
The software does not supporting English version currently.
Special Bluetooth
module (MCTC-
BTM-A) and cell
phone host EDSAP
required
Residential
monitoring
The control system can be connected to the terminal in the
monitoring room. By using the NEMS software, you can view the
oor position, running direction, and fault state of the elevator.
NEMS, accessories,
and MCTC-MIB
required
IC card
Passengers need to use the IC card to go to oors that require
authorization.
IC card required