For SLIU PKG Setup (SL1100)
Physical Port Number 01 ~ 08
Item No. Item Input Data Default
01 Logical Port Number 0 ~ 120 0
03 Transmit Gain Level (S-Level) 1 ~ 63 (- 15.5 ~ + 15.5 dB) 32 (0 dB)
04 Receive Gain Level (R-Level) 1 ~ 63 (- 15.5 ~ + 15.5 dB) 32 (0 dB)
05 Select port type
0=SLT
1 = Door Phone
0
For COIU Unit Setup
Physical Port Number 1 ~ 4
Item No. Item Input Data Default Note
01 Logical Port Number
1 ~ 48 (SL1000)
1 ~ 36 (SL1100)
0
02 Select port type
0 = Trunk
1 = Audio Port
0 (SL1000)
For BRIU PKG Setup
ISDN Line Number 01 ~ 02
Item No. Item Input Data Default Note
01 ISDN Line Mode 0 = No setting
1 = T-Point
2 = S-Point
3 ~ 5= Not Used
6 = S-Point (Leased Line)
1
02 Logical Port Number
The starting port num-
ber of a BRI line is dis-
played. Two logic ports
are automatically as-
signed to a BRI line.
[0:Nosetting]=0
[1 : T-Point] = 200
[2:S-Point]=512
[3~5:NWMode] = 0
[6 : S-Point (Leased Line)]=1~512
0
03 Connection Type 0 = Point-to-Multipoint
1 = Point-to-Point
0
04 Layer 3 Timer Type
Each timer value of
Layer 3 is set up for ev-
ery type using Program
81-06 (T-Bus).
1~5 1
05 CLIP Information Announce-
ment
Based on this setting, the system
includes a Presentation Allowed
(1) or Presentation Restricted (0)
in the Setup message to allow or
deny the Calling Party Number.
Program 15-01-04 must also be
set to 1 if this option is enabled.
0=No
1=Yes
1