Item No. Item Input Data Default Note
21 Number of Ports 0 = Auto
1=4Ports
2=8Ports
3=12Ports
4=16Ports
5=20Ports
6=24Ports
7=28Ports
0
For PRI (T1) PKG Setup
Physical Port Number 01 ~ 24
Item No. Item Input Data Default
01 Logical Port Number
The start port number of a T1 line is dis-
played, and 24 logic ports are automatically
assigned to a DTI (T1) line.
1 ~ 126 (SL1000)
1 ~ 96 (SL1100)
0
02 T1 Signal Format Selection 0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
0
03 Zero Code Suppression 0 = B8ZS
1 = AMI/ZCS
0
04 Line Length Selection 0=0feet~133feet
1 = 133 feet ~ 266 feet
2 = 266 feet ~ 399 feet
3 = 399 feet ~ 533 feet
4 = 533 feet ~ 655 feet
0
05 T1 Clock Source 0 = Internal
1 = External
1
06 Number of Ports 0 = Auto
1=4Ports
2=8Ports
3=12Ports
4=16Ports
5=20Ports
0
For E1 PKG Setup
Physical Port Number 01 ~ 30
Item No. Item Input Data Default
01 Logical Port Number 1 ~ 126 (SL1000)
1 ~ 96 (SL1100)
0
02 Number of channels 0~30 0
04 E1 Clock Source 0 = Internal
1 = External
1
05 Transmit Pulse Mask 0=01to133feet
1 = 133 to 266 feet
2 = 266 to 399 feet
3 = 399 to 533 feet
4 = 533 to 655 feet
0
06 Frame Type 0 = Double Frame (no CRC-4)
1 = Multiframe Structure (CRC-4)
0
07 Line Coding 0 = AMI
1 = HDB3
1