Item No. Item Input Data Default
10 Receive Input Threshold 0 = 0.91/1.70 V
1 = 0.74/0.84 V
2 = 0.59/0.84 V
3 = 0.42/0.45 V
4 = 0.32/0.45 V
5 = 0.21/0.20 V
6 = 0.16/0.10 V
7 = 0.10/not defined
2
For VoIPDB PKG Setup
Physical Port Number 01 ~ 16
Item No. Item Input Data Default
01 Trunk Logical Port Number 1 ~ 126 (SL1000)
1 ~ 96 (SL1100)
0
02 Trunk Type 0=H.323
1=SIP
1
For E1IU Unit Setup
Item No. Item Input Data Default Note
01 Logical Port Number 0 ~ 200 0
02 Number of channels 0~30 0
03 Reserve
04 E1 Clock Source
0 = Internal
1 = External
1
05 Transmit pulse mask
0=0to133feet
1 = 133 to 266 feet
2: = 266 to 399 feet
3 = 399 to 533 feet
4 = 533 to 655 feet
0
06 Frame Type
0 = Double Frame ( no
CRC-4)
1 = CRC-4 multiframe
structure
0
07 Line Coding
0 = AMI
1 = HDB3
1
08 Reserve
09 Not Used
10 Receive input Threshold
0=0.91/1.70V
1=0.74/0.84V
2=0.59/0.84V
3=0.42/0.45V
4=0.32/0.45V
5=0.21/0.20V
6=0.16/0.10V
7 = 0.10 / not defined
2
Conditions
When changing a defined terminal type, first set the type to 0 and then plug the new device in to
have the system automatically define it, or redefine the type manually.
The system must have a unit installed to view/change the options for that type of unit.
ISSUE 1.0SL1000/SL1100
Program
10
Program 10 : System Configuration Setup2-10