Dial Action Table Default Settings
Key
Dial Action Table 1 Dial Action Table2~16
Action Data Action Data
7 0 (UND) 0 0 (UND) 0
8 0 (UND) 0 0 (UND) 0
9 6 (Hang Up) 0 0 (UND) 0
0 2 (UTRF) 200 0 (UND) 0
*
3 (REC1) IXXX 0 (UND) 0
# 5 (LOGON) IXXX 0 (UND) 0
TIMEOUT 2 (UTRF) 200 0 (UND) 0
TIMEOUT provides the routing for rotary dial callers.
Note
IfActionisset0or6skipDatasetting.
"XXX"= change as it fit
The “Data” data needs to follow these rules below.
0 (UND) = none
1 (TRF) = dial data (any), X, I, N, or P
2 (UTRF) = dial data (any), X, I, N, or P
3 (REC1) = mailbox number (subscriber or group)
4 (REC2) = mailbox number (subscriber or group)
5 (LOGON) = mailbox number (subscriber or group)
6 (HANGUP) = none
7 (GOTO) = routing mailbox number index (1 ~ 32)
Otherwise it will not be routed properly.