Item
No.
Item Input Data Description Default
01 Terminal Type 0 = No Setting
1 = Multiline Telephone
10 = DSS Console
0
02 Logical Port Number 0 = No Setting
1 = Multiline Telephone (1 ~
128 )
10 = DSS Console (1 ~ 12)
0
08 Multiline T
elephone Type 0 = DT3**
1 = DT4**
3 = SL1100 2W
4 = SL2100 2W
0
09 Item Side option information 0 = No Option
4 = EHS
0
10 Bottom option information 0 = None
4 = WHA
5 = BCA
0
For SLI PKG Setup
Physical Port Number 1 ~ 8
Item No. Item Input Data Description Default
01 Logical Port Number 0 ~ 128 0
03 Transmit Gain Level (S-Lev-
el)
1 ~ 57 (- 15.5 ~ + 12.5 dB) 32 (0 dB)
04 Receive Gain Level (R-Lev-
el)
1 ~ 57 (- 15.5 ~ + 12.5 dB) 32 (0 dB)
05 Select port type 0 = SLT
1 = Door Phone
HW switch can be change
SLT or Door Phone.
0
For COI PKG Setup
Physical Port Number 1 ~ 3
Item No. Item Input Data Default
01 Logical Port Number 0 ~ 128 0
For BRI PKG Setup
ISDN Line Number 1 ~ 2
Item No. Item Input Data Description Default
01 ISDN Line Mode 0 = No Setting
1 = T-Point
2 = S-Point
3 ~ 5= Not Used
6 = S-Point (Leased Line)
1
SL2100 ISSUE 2.0
2-10 Program 10 : System Configuration Setup
Program
10