-202-
Library error code (8/16)
Cannot execute calibration because picker has a
medium.
(FRU)
Maintenance chassis, CONTROLLER BOARD
1. To power cycle the library.
2. Unless calibration operated, this error
does not occur.
Cannot execute calibration because magazine is
not inserted.
(FRU)
Maintenance chassis, CONTROLLER BOARD
1. To power cycle the library.
2. Unless calibration operated, this error
does not occur.
Defect in calibration data.
(FRU)
Maintenance chassis, CONTROLLER BOARD
1. To power cycle the library.
2. Unless calibration operated, this error
does not occur.
Cannot detect I/O slot sensor open state in I/O
slot sense operation during calibration.
(FRU)
I/O Slot Sensor, CONTROLLER BOARD
To power cycle the library.
Cannot get/check medium and read barcode
because picker has a medium.
(FRU)
Maintenance chassis, CONTROLLER BOARD
1. Check picker if it has a medium.
2. To power cycle the library.
Cannot put medium because picker does not
have a medium.
(FRU)
Maintenance chassis, CONTROLLER BOARD
1. Check picker if it has a medium.
2. To power cycle the library.
Cannot eject medium because drive does not
become condition of EJECT after 200 seconds
in getting medium from drive.
(FRU)
Drive, CONTROLLER BOARD
1. To power cycle the library.
2. Move the medium manually via Web
or Operator Panel.
3. Check the medium.
Drive does not become condition of MOUNT
after 200 seconds in putting medium to drive.
(FRU)
Drive, Maintenance chassis, CONTROLLER
BOARD
1. To power cycle the library.
2. Check the medium and exchange
medium.
Drive does not become condition of SET after 3
seconds in putting medium to drive.
(FRU)
Drive, Maintenance chassis, CONTROLLER
BOARD
1. To power cycle the library.
2. Check the medium and exchange
medium.
In medium picking or putting, drive interface
error detected or drive is not connected.
(FRU)
Drive, Maintenance chassis, CONTROLLER
BOARD
To power cycle the library.