-222-
Expired cleaning media
・Exchange the cleaning cartridge.
Invalid cleaning tape
・Exchange the cleaning cartridge.
The drive has a hardware fault that requires a reset to
recover.
・Turn the power off and on again.
・Call to maintenance staff.
The drive has a hardware fault that is not related to the
read/write operation or the drive requires a power cycle to
recover.
・Call to maintenance staff.
The drive has identified an interface fault.
・Check host interface connection.
Eject media
・Eject the tape cartridge.
・Exchange the tape cartridge.
Firmware download failed
・Confirm the firmware file.
・Try firmware download again.
The drive’s temperature limits are exceeded.
・Please check the installation environment of the library.
The drive’s voltage limits are exceeded.
・Call to maintenance staff.
Predictive failure of drive hardware
・Execute the corresponding error if other as has occurred.
Diagnostics required
・Call to maintenance staff.
Tape Directory Invalid at
Unload
Tape directory invalid at unload
・Exchange the tape cartridge if the phenomenon occurs
again.
Tape System Area Write
Failure
Tape system area write failure
・Exchange the tape cartridge if the phenomenon occurs
again.
Tape System Area Read
Failure
Tape system area read failure
・Exchange the tape cartridge if the phenomenon occurs
again.
Loading failure
・Exchange the tape cartridge.
・Call to maintenance staff.
Unrecoverable Unload
Failure
Unrecoverable unload failure
・Please remove the tape cartridge from the drive.
Please refer to Section 4.7.2 if you take out in the
operation of the library apparatus.
・Call to maintenance staff.
WORM Medium –
Integrity Check Faied
(WORM Medium - integrity check failed) set when the drive
determines that the data on tape is suspect from a WORM
point of view.
・Exchange the tape cartridge.
WORM Medium – Over
Write Attempted
(WORM Medium - Overwrite Attempted) set when the drive
rejects a Write operation because the rules for allowing
WORM writes have not been met.
・Exchange the tape cartridge.