UM10360 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2013. All rights reserved.
User manual Rev. 3 — 19 December 2013  460 of 841
NXP Semiconductors
UM10360
Chapter 19: LPC176x/5x I2C0/1/2
 
Table 400. Slave Receiver mode
I2CSTAT 
Status 
Code
Status of the I
2
C-bus 
and hardware
Application software response Next action taken by I
2
C hardware
To/From I2DAT To I2CON
STA STO SI AA
0x60 Own SLA+W has been 
received; ACK has been 
returned.
No I2DAT action 
or
X 0 0 0 Data byte will be received and NOT ACK 
will be returned.
No I2DAT action X 0 0 1 Data byte will be received and ACK will be 
returned.
0x68 Arbitration lost in 
SLA+R/W as master; 
Own SLA+W has been 
received, ACK returned.
No I2DAT action 
or
X 0 0 0 Data byte will be received and NOT ACK 
will be returned.
No I2DAT action X 0 0 1 Data byte will be received and ACK will be 
returned.
0x70 General Call address 
(0x00) has been 
received; ACK has been 
returned.
No I2DAT action 
or
X 0 0 0 Data byte will be received and NOT ACK 
will be returned.
No I2DAT action X 0 0 1 Data byte will be received and ACK will be 
returned.
0x78 Arbitration lost in 
SLA+R/W as master; 
General Call address 
has been received, ACK 
has been returned.
No I2DAT action 
or
X 0 0 0 Data byte will be received and NOT ACK 
will be returned.
No I2DAT action X 0 0 1 Data byte will be received and ACK will be 
returned.
0x80 Previously addressed 
with own SLA address; 
DATA has been received; 
ACK has been returned.
Read data byte 
or
X 0 0 0 Data byte will be received and NOT ACK 
will be returned.
Read data byte X 0 0 1 Data byte will be received and ACK will be 
returned.
0x88 Previously addressed 
with own SLA; DATA 
byte has been received; 
NOT ACK has been 
returned.
Read data byte 
or
0 0 0 0 Switched to not addressed SLV mode; no 
recognition of own SLA or General Call 
address.
Read data byte 
or
0 0 0 1 Switched to not addressed SLV mode; 
Own SLA will be recognized; General Call 
address will be recognized if 
I2ADR[0] = logic 1.
Read data byte 
or
1 0 0 0 Switched to not addressed SLV mode; no 
recognition of own SLA or General Call 
address. A START condition will be 
transmitted when the bus becomes free.
Read data byte 1 0 0 1 Switched to not addressed SLV mode; 
Own SLA will be recognized; General Call 
address will be recognized if 
I2ADR[0] = logic 1. A START condition will 
be transmitted when the bus becomes 
free.
0x90 Previously addressed 
with General Call; DATA 
byte has been received; 
ACK has been returned.
Read data byte 
or
X 0 0 0 Data byte will be received and NOT ACK 
will be returned.
Read data byte X 0 0 1 Data byte will be received and ACK will be 
returned.