Technical Data
16 - 5
CPC 100 Outputs
Important: Due to safety-relevant issues regarding CPC 100 high-current and
high-voltage outputs, also read ”High-voltage and high-current outputs” on page
1-9.
High-Current and High-Voltage Outputs
The high-current and high-voltage outputs are all situated at the left-hand side
of CPC 100.
800A AC output
While using the 800A AC output, disconnect any cables that may be plugged in
to the 400A DC output. These outputs are internally connected.
Table 2:
800A AC output
technical data
800A AC output
Connection 10mm connectors
Insulation Internally connected to the 400A DC output, insulated
against all other inputs and outputs.
Voltage with reference to earth must not exceed
300V
rms
and 420V
peak
on either socket.
Reinforced insulation against mains power supply, all
interfaces and other safety low-voltage circuits.
Output power at: typical app.
power S
max
typical time
t
max
duty cycle
t
on
/t
off
frequency
800A
600A
400A
300A
200A
4800VA
3780VA
2560VA
1940VA
1300VA
25s
200s
500s
15min
> 2hrs
5s / 55s
5s / 25s
5s / 5s
10s / 5s
cont. ON
50 ... 60Hz

Table of Contents

Other manuals for Omicron CPC 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omicron CPC 100 and is the answer not in the manual?

Omicron CPC 100 Specifications

General IconGeneral
BrandOmicron
ModelCPC 100
CategoryTest Equipment
LanguageEnglish

Related product manuals