Setting Option/Setting range Pages
I/O setting
[I/O]
Non
measurement
setting
[HLD.RST]
Non
measurement
setting
[HLD.RST]
Keep [KEEP]/Clamp [CLAMP]
*
p.4-28
Analog
output
[ANALOG]
Current output: MIN [MIN]
(Approx. 3.4 mA)/4 mA/5 mA/.../19
mA/20 mA/MAX [MAX]
(Approx. 21 mA) (Default: MAX)
Voltage output: MIN [MIN]
(Approx. -10.8 V)/-10 V/-9 V/.../9 V/
10 V/MAX [MAX] (Approx. 10.8 V)
(Default: MAX)
p.4-30
Binary
output
[BINARY]
MAX [MAX]
*
/MIN [MIN]
Judgment
[JUDGE]
Output object
[OUTPUT]
Output object
[OUTPUT]
TASK1 [TASK1]
*
/TASK2 [TASK2]/
TASK3 [TASK3]/TASK4 [TASK4]
p.4-18
Hysteresis
[HYS]
Hysteresis
[HYS]
0 to 99.9999 mm
(Default: 0.05 % of measurement
range)
p.4-18
Timer
[TIMER]
Timer
[TIMER]
Off
*
[OFF]/Off delay [OFF.DLY]/On
delay [ONDLY]/1 shot [1SHOT]
p.4-19
Timer time
[TIME]
1 to 5000 ms (Default: 1)
Analog output
[ANALOG]
Voltage or
current
*
[V OR C]
Voltage or
current
[V OR C]
Voltage output
*
/Current output
p.4-12
Output object
[OUTPUT]
Output object
[OUTPUT]
OFF [OFF]/TASK1 [TASK1]
*
/
TASK2 [TASK2]/TASK3 [TASK3]/
TASK4 [TASK4]
p.4-13
Focus
[FOCUS]
Focus
[FOCUS]
Off [OFF]
*
/On [ON]
p.4-14
Focus
Current/
Voltage 1
[CUR1]/
[VOLT1]
Current: 4/5/6/7/8/9/10/11/12/13/14/
15/16/17/18/19/20 mA
(Default: 4 mA)
Voltage: -10/-9/-8/-7/-6/-5/-4/-3/-2/-
1/0/1/2/3/4/5/6/7/8/9/10 V
(Default: -10 V)
Measurem
ent value 1
[MEAS1]
-999.999999 to 999.999999 mm
(Default: -0.5)
Focus
Current/
Voltage 2
[CUR2]/
[VOLT2]
Current: 4/5/6/7/8/9/10/11/12/13/14/
15/16/17/18/19/20 mA
(Default: 20 mA)
Voltage: -10/-9/-8/-7/-6/-5/-4/-3/-2/-
1/0/1/2/3/4/5/6/7/8/9/10 V
(Default: 10 V)
Measurem
ent value 2
[MEAS2]
-999.999999 to 999.999999 mm
(Default: 0.5)
Calibration
[CALIB]
Calibration
[CALIB]
Off
*
/On
p.4-16
Calibration
Current/
Voltage 1
[CUR1]/
[VOLT1]
Current: 4/5/6/7/8/9/10/11/12/13/14/
15/16/17/18/19/20 mA
(Default: 4 mA)
Voltage: -10/-9/-8/-7/-6/-5/-4/-3/-2/-
1/0/1/2/3/4/5/6/7/8/9/10 V
(Default: -10 V)
Calibration
value 1
[ADJ1]
-999 to 999 (Default: 0)
Calibration
Current/
Voltage 2
[CUR2]/
[VOLT2]
Current: 4/5/6/7/8/9/10/11/12/13/14/
15/16/17/18/19/20 mA
(Default: 20 mA)
Voltage: -10/-9/-8/-7/-6/-5/-4/-3/-2/-
1/0/1/2/3/4/5/6/7/8/9/10 V
(Default: 10 V)
Calibration
value 2
[ADJ2]
-999 to 999 (Default: 0)
*
The same output destination is set for all banks. The output destination cannot be set separately for individual banks.