Errors and Warnings
15-2
15.1 About Errors and Warnings
15.1.1 Errors and Warnings
If any operational unconformity occurs in the positioning unit, an error or warning will occur.
When an error or warning occurs, the following operation will be performed.
Errors
Occurs in any abnormal conditions. When a motor is operating, the operation stops.
The motor stopped due to the occurrence of error will not be activated until the error clear is
executed.
Warnings
Occurs if there is any operational unconformity but not abnormal.
The operation can continue even after the occurrence of warnings, and the motor continues
running if the motor is operating.
15.1.2 Check and Clearing with Configurator PM7
It is possible to check and clear data on an axis-by-axis basis by selecting [Online] [Status
monitor] on the Configurator PM7 programming tool.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 and is the answer not in the manual?

Panasonic FP7 Specifications

General IconGeneral
SeriesFP7
ManufacturerPanasonic
Input Voltage24 V DC
Data MemoryVaries by model
DimensionsVaries by model
WeightVaries by model
TypeProgrammable Logic Controller (PLC)
Output TypeRelay, Transistor
Number of InputsVaries by model
Number of OutputsVaries by model
Communication PortsEthernet, RS232C, RS485