17.4 Details of Common Area in Unit Memory
17-17
17.4.2 Setting Parameter Control Area
Set a recalculation starting table number in order to recalculate the positioning data in the
standard area.
Unit
memory no.
(Hex)
Name Description Default
Setting
range
Set
unit
UM 00085
Recalculation
starting table
number
If the ON state of the recalculation request signal (contact
Y7) is detected, the positioning unit will recalculate
positioning data on all axes beginning with this table
number up to number 600.
1 1 to 600
−
17.4.3 Operating Speed Factor Area
Unit
memory no.
(Hex)
Name Description Default
Setting
range
Set
unit
UM 00088
Operating
speed factor
It is possible to perform all types of axial control
(positioning, JOG, and home return control) at a magnified
rate of this speed.
Values can be input in percent within a range of 1 to 100 (%).
100 1 to 100 %
17.4.4 Axis Group Setting Area
Set an interpolation group on an axis-by-axis basis in this area.
Unit
memory no.
(Hex)
Name Description
UM 000B0
Group A axis
settings
Make independent and interpolation settings for each axis in this area. In the case of
interpolation, each axis belongs to group A, B, C, or D. For example, if the 1st, 2nd,
and 3rd axes belong to group A for three-axis interpolation, set the three
corresponding bits for the interpolation settings for group A to 1. In the case of single
independent settings, the axis will not belong to any group. Then turn ON the
corresponding bit for the following independent axis settings.
A maximum of three axes can be set for interpolation per group. Duplicated settings
for the same axis in different groups are not possible.
bit Name Default Description
0 Group attribute of 1st axis 0
0: Not belongs to any group.
1: Belongs to a group.
An error occurs if four or more bits for
the same group are set to 1 or the
same axis is set to 1 for another group.
1 Group attribute of 2nd axis 0
2 Group attribute of 3rd axis 0
3 Group attribute of 4th axis 0
15 to 4 − - −
UM 000B1
Group B axis
settings
UM 000B2
Group C axis
settings
UM 000B3
Group D axis
settings
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com