Wiring
3-8
3.3 Supply of Power to Drive Internal Circuit
3.3.1 Line Driver Output
External power
supply
Positioning unit
Motor driver
Pulse
command
Pulse command
output
A1, A2, A10, A11
Pulse command
input
B1, B2, B10, B11
+5V DC
DC/DC
converter
A20
B20
GND
+24V DC
External power supply
The illustration shows one signal component
extracted from the overall configuration.
Usable voltage range
21.4 to 26.4V DC
Current
consum-
ption
4-axis type
2-axis type
90 mA or less
50 mA or less
3.3.2 Transistor Output
It is possible to get power for the pulse instruction output circuit from the 5-V DC output
terminal (pins A1, A2, A10, and A11).
Positioning unit
Motor driver
Pulse command
input
at 5V output
A1, A2,
A10,A11
Pulse command
output
B1,B2,B10,B11
15 mA per signal
can be used as a
guide
External power supply
Usable voltage range
Current
consum-
ption
4-axis type
2-axis type
21.4 to 26.4V DC
90 mA or less
50 mA or less
A20
B20
+24V DC
GND
+5V DC
DC/DC
converter
Pulse
command
Note:
Make sure that a current not in excess of 15 mA is provided for each signal in the case of
using pulse transistor output (open collector output). Add appropriate resistance if the current
exceeds 15 mA.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com