EasyManua.ls Logo

Panasonic FP7

Panasonic FP7
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Unit Allocation and
Parameter Settings
5-12
5.5 Creating Positioning Data Table
5.5.1 Construction of Positioning Data Table
Use the Configurator PM7 to allocate the positioning data table. The following procedure is
explained on the condition that the Configurator PM7 has already started.
Initial display screen of Configurator PM7
Sheets are divided for each axis, and 600 tables ranging No. 1 to No. 600 can be set.
Setting items
Parameter name Description
Operation pattern Select one from the following operation patterns.
E point: Executes the trapezoidal control of only one table.
C point: Executes the trapezoidal control continuously. Specify an end point (E point)
at the end of the continuance point (C-point) control.
P point: Executes the continuous speed change control. Specify an end point (E
point) at the end of the pass point (P-point) control.
J point: Executes speed control. Specify an end point (E point) at the end of the
speed control (J point).
X-axis control method Select either increment or absolute coordinate.
X-axis movement
amount
Input the movement amount of X-axis. The movement amount depends on the unit
system specified in the parameter settings.
Acceleration/deceleration
pattern
Select the acceleration/deceleration pattern.
Acceleration time (ms) Set the acceleration time. Set in ms.
Deceleration time (ms) Set the deceleration time. Set in ms.
Dwell Time (ms)
Set the time from when the positioning instruction in the end point control completes
until the positioning done flag turns ON. For the continuance point control, it is the
wait time between each table. For the pass point control, the dwell time is ignored.
Auxiliary output
Set the auxiliary output code. When the auxiliary output is set to enable in the
parameter settings, the auxiliary output code specified here is output.
(Note 1): The details for the settings in each parameter are indicated in the guidance bar.
(Note 2): In the case of selecting interpolation control, interpolation, Y-axis movement amount, X-axis auxiliary point,
Y-axis auxiliary point, and interpolation speed as items are displayed as well.