17.7 Unit Memory Synchronous Control Setting Area
17-69
17.7.2 Detailed Information on Synchronous Control Setting Area
Make synchronous control settings in this area. These values set in the Configuration menu
will be stored automatically. Therefore, individual settings are not necessary.
Synchronous control common setting area
Offset
address
Name Default Description
000H
Each axis
synchronous
master axis
selection
0000H
Set the master axis for each axis.
Set value Master axis
0000H No synchronous master axis or the target set axis is the
master axis.
0001H 1st axis
0002H 2nd axis
0003H 3rd axis
0004H 4th axis
0010H Virtual axis
0021H Pulse input 1
0022H Pulse input 2
0023H Pulse input 3
0024H Pulse input 4
001H
Each axis
synchronous output
function
selection
0000H
The state of the synchronous operating function set for the axis
is stored.
bit Functions Setting
0 Electronic gear setting 0: Yes
1: No
1 Clutch operation settings
2 Electronic cam operation
settings
3-15 Area reserved for system
Electronic gear setting area
Offset
address
Name Default Description
010H
- 011H
Each axis gear ratio
numerator
1 1 to 2,147,483,647
012H
- 013H
Each axis gear ratio
denominator
1 1 to 2,147,483,647
014H
Each axis gear
change time
1 1 to 10000
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com