13.7 Startup speed
13-17
13.7 Startup speed
The positioning unit allows startup speed settings for the startup of each type of operation.
The startup speed is available for positioning, JOG operation, and home return control.
Setting method of startup speed
Set the startup speed in the parameter-setting menu for each axis of the Configurator PM7.
Cautions for start speed settings
1. The startup speed will apply to the end of operation as well. The speed at the end of
operation cannot be changed.
2. The home return creep speed at the time of a home return will not be influenced by the
start speed.
3. The target speed of each type of operation is not influenced by the start speed. The
positioning unit operates at the preset target speed regardless of the preset startup speed.