15.4 List of Warning Codes
15-15
Error
code
Error name Description Object Recovered Countermeasures
B045H
Synchronous
axis difference
check warning
The difference between
the movement amounts
of the target axes in
synchronous operation
has exceeded the
specified difference
threshold.
This warning occurs
when the synchronous
operation mode and
synchronous difference
check function are set
to Warning.
Each
axis
Yes
Check the operation of the target
axes for the synchronous operation.
B046H
Automatic
movement
amount check
warning
The automatic
movement amount
check function has
detected that the
difference between the
instruction value and
feedback value is in
excess of the preset
automatic movement
amount.
This warning occurs
when the operation of
the automatic check
function of movement
amount is set to
Warning.
Each
axis
Yes
Check the operation of the target
axes.
B304H
Recalculation
error warning
An error has occurred
while recalculation
processing is in
process.
Each
axis
Yes
Check the settings for each axis
parameter and interpolation group.