Chapter 15: Maintaining Your Library
Maintenance Actions
640 Quantum Scalar i6000 User’s Guide
• If there are multiple failed results in an area, review the area to
make sure it is not prone to problems. Also run the library
alignment test (part of the installation verification or partial frame
test) to make sure the library is level.
• If there are a large number of issues, use rubbing alcohol to clean
the picker fingers and the detents in the side of the tapes.
• If the problems persist, you may need to replace the picker
assembly.
See Figure 74 on page 641.

Table of Contents

Other manuals for Quantum Scalar i6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i6000 and is the answer not in the manual?

Quantum Scalar i6000 Specifications

General IconGeneral
Form FactorRack-mountable
InterfaceFibre Channel, SAS
Product TypeTape Library
CoolingRedundant cooling fans
DimensionsVaries by configuration
WeightVaries by configuration
Operating Humidity20% to 80% non-condensing
ScalabilityScalable
Drive TypesLTO
RedundancyRedundant power supplies
ManagementWeb-based management
Tape TechnologyLTO
Supported MediaLTO Ultrium 9, LTO Ultrium 8, LTO Ultrium 7, LTO Ultrium 6
Power SupplyRedundant power supplies
Non-operating Humidity5% to 95% non-condensing