5.8 PASSWORD PROTECTION
NOTE
This is the only page where the user ID and password are discussed. This page can be
removed from the Instruction Manual for added security.
Password protection is used in this system to prevent unauthorized persons from gaining access to the
Network Management Software settings and parameters.
5.8.1 ENTERING THE NETWORK MANAGEMENT SOFTWARE
Upon starting the Network Management Software the user will be presented with a sign on screen. The
user must enter a user ID and a password to continue. Enter the word “control” for the user ID, then hit
the “enter” key. Enter the word “password” for the password, then click on “OK”. This will allow the
main window to be displayed.
5.8.2 CHANGING THE PASSWORD
The user ID or password can be changed by entering the security file window. This window is entered
from the main window by clicking on Setup and then clicking on Setup User ID. In this window, other
user ID’s can be setup as “Master” which means they can setup or change other users (including other
“masters” or “users”). A “user” class can not set up other users or see other passwords.
5.8.3 BYPASSING THE SIGN ON SCREEN
Two keywords in the INI file are used in conjunction with security. If the user enters the INI file and
then enters a value for USERID and for PASSWORD, and these are valid values the sign on screen
will be bypassed. A user that is not interested in security can change their INI file after the first sign on
and then not have to enter the sign on screen to get into the main Network Management Software
window. At a later date the security can be reactivated.
From the main window click on Setup, and then click on Edit INI. This will bring you to the software
settings window. Click on the Expert Mode button. This will bring you to the rfl.ini file. Scroll down to
the [SECURITY] section and type in the following two lines:
USERID=CONTROL
PASSWORD=PASSWORD
Then exit the rfl.ini window and click on the Yes buttons to get back to the main window. The sign on
screen will now be bypassed.