Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DS-961D RFL Electronics Inc.
October 14, 2004 6 (973) 334-3100
8. Select the time slot using DIP switches SW2-1 to SW2-5.
9. Set for use in a terminal or drop/insert multiplexer by using DIP switch SW2-6.
10. Select the data rate by using DIP switches SW3-1 and SW3-2. (See Table 5)
11. Select the buffer-in timing by using DIP switch SW3-4. If using three channel mode, this
should be set to the UP position.
12. If using internal DS-961D module timing, set each channel to normal or inverted clock by
using DIP switches SW3-5 to SW3-9.
13. Set the loop switch, SW3-10, to the UP position,.
14. If you plan to operate the RFL DS-961D module under local control, perform the following
steps; otherwise, go to step 15 for remote control.
a. Set to local control by placing DIP switch SW1-7 in the OFF position.
b. Turn service on by placing DIP switch SW1-8 in the OFF position.
c. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
d. Go to step 16.
15. If you plan to operate the RFL DS-961D module under remote control, perform the following
steps:
a. Set to local control by placing DIP switch SW1-7 in the OFF position.
b. Turn service off by placing DIP switch SW1-8 in the ON position.
c. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
d. Wait 15 seconds for the RFL DS-961D module’s parameter settings to be loaded into
the shelf Common Module.
e. Pull the module out of the shelf and place DIP switch SW1-7 in the ON position.
f. Slide the module back into the shelf.
g. Verify the module configuration through remote control by issuing a “CONFIG?”
query. See the Remote Control Interface section of this Instruction Data Sheet
for an explanation of the “CONFIG?” response.
h. Turn service on through remote control by issuing a “SRVC=ON” command.
The RFL DS-961D’s operating parameters can now be changed by remote
control. See the Remote Control Interface section of this Instruction Data
Sheet for more information.
i. Go to step 16.