Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL VF-8A RFL Electronics Inc.
August 6, 2010 13 (973)
334-3100
16. If you plan to operate the RFL VF-8A module under remote control, perform the following
steps:
a. Set to local control by placing DIP switch SW1-7 in the UP position.
b. Turn service off by placing DIP switch SW1-8 in the DOWN position.
c. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
d. Wait 15 seconds for the RFL VF-8A module’s parameter settings to be loaded into the
shelf Common Module.
e. Pull the module out of the shelf and place DIP switch SW1-7 in the DOWN position.
Do not move SW1-8.
f. Slide the module back into the shelf.
g. Verify the module configuration through remote control by issuing a “CONFIG?”
query. See the Remote Control Interface section of this Instruction Data Sheet for an
explanation of the “CONFIG?” response.
h. Turn service on through remote control by issuing a “SRVC=ON” command.
The RFL VF-8A’s operating parameters can now be changed by remote
control. See the Remote Control Interface section of this Instruction Data
Sheet for more information.
i. Go to step 17.
17. On the Module Record Card located to the right of the shelf, record the channel bank type, time
slot, and any other pertinent information.