EasyManua.ls Logo

RFL Electronics IMUX 2000 - Page 627

Default Icon
982 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL VF-8A RFL Electronics Inc.
August 6, 2010 23 (973)
334-3100
“S” CODES
“S” codes appear in response to a “STATUS?” query. There is one “S” code for the RFL VF-8A when
operated in T1 or E1 systems. Like the “P” code, this number is displayed in both decimal and binary
form. The six least significant digits of the binary number represent the conditions shown in Table 8.
The two most significant digits are not used.
A typical response to a “STATUS?” query looks like this:
* OK
CHANNEL CARD 3, TYPE 125
S01 = 2 (B00000010);
Table 8. Remote status messages (“S” codes) for T1/E1
S CODE Position Value Description
S1 B 0 0 0 1 1 0 1 0 0 Valid configuration
- -
- - - - -
1 Inval
id configuration
B 0 0 0 0 0 0 0 0 0 Local ringing
- - - - -
- -
1 Local not
ringing
B 0 0 0 0 0 0 0 0 1 Remote connected
- -
- - - - -
0 Remote not connected
B 0 0 0 0 0 0 0 0 1 Local connected
- -
- - - - -
0 Local not connected
B 0 0 0 0 0 0 0 0 0 Remote ringing
- -
- - - - -
1 Remote not ringing
B 0 0 0 0 0 0 0 0 0 Timeout active (50 second timer exceeded)
- -
- - - - -
1 Timeout not active