SERVICE PROGRAM MODE
B121 Series/B259 Series 5-20 SM
SP7-XXX (Data Log)
7001*
Total Operation
7001 1 Displays the total operation time (total drum rotation time).
7401*
Counter–SC Total [0 ~ 9999 / 0 / 1/step]
7401 1 Displays how many times SC codes are generated.
7403*
SC History
7403 1 Displays the histories of the latest 10 SC codes.
7502*
Counter–Paper Jam [0 ~ 9999 / 0 / 1/step]
7502 1 Displays the total number of copy paper jams.
7503*
Counter–Orgn Jam [0 ~ 9999 / 0 / 1/step]
7503 1 Displays the total number of original jams,
Counter-Each P Jam [0 ~ 9999 / 0 / 1/step]
7504*
Displays the total number of the paper jams classified by timing and location.
Counter-Each P Jam (At power on) 7504 1
Paper jam occurs at power on.
Counter-Each P Jam (Off-Regist NoFeed) 7504 10
Paper does not reach the registration sensor (from a paper tray).
Counter-Each P Jam (Off-1 Vertical SN) 7504 11
Paper does not reach the relay sensor.
Counter-Each P Jam (On-1 Vertical SN) 7504 12
Paper is caught at the relay sensor.
Counter-Each P Jam (Off-2 Vertical SN) 7504 21
Paper does not reach the vertical transport sensor.
Counter-Each P Jam (On-2 Vertical SN) 7504 22
Paper is caught at the vertical transport sensor.
Counter Each P Jam (Off-3 Vertical SN) 7504 31
Paper does not reach the vertical transport sensor in the optional paper feed unit.
Counter Each P Jam (On-3 Vertical SN) 7504 32
Paper is caught at the vertical transport sensor in the optional paper feed unit.
Counter-Each P Jam (Off-Regist Bypass) 7504 50
Paper does not reach the registration sensor (from the by-pass tray).
Counter-Each P Jam (Off-Regist Duplex) 7504 60
Paper does not reach the registration sensor during reverse-side printing (for
duplex printing).
Counter-Each P Jam (On-Regist SN) 7504 70
Paper is caught at the registration sensor.
Counter-Each P Jam (On-Exit SN) 7504 120
Paper is caught at the exit sensor (previous page).
Counter-Each P Jam (Off-Exit SN) 7504 121
Paper does not reach the exit sensor.
Counter-Each P Jam (On-Exit SN) 7504 122
Paper is caught at the exit sensor.