SERVICE PROGRAM MODE
SM 5-41 B121 Series/B259 Series
Service
Tables
SP5-XXX (Mode)
5001
All Indicators On
5001 1 All LEDs turn on. The LCD turns on or off every 3 seconds. Press the reset key to
end this program.
SSP
5044*
Operation Panel Bit Switch DFU
SSP
5104*
A3/DLT Double Count [0 = Enabled / 1 = Disabled /
2 = Disabled if the size is undetected]
5104 1 Selects whether the machine counts twice for each sheet of A3/11"x 17". If this is
set to “Yes” is selected, the total (mechanical) counter and the current user counter
will both increment by two for each A3/11" x 17" sheet.
5113*
Optional Counter Type 0: None
5: MF key card (Peace) Japan Only
11: MF key card (Increment)
12: MF key card (Decrement)
NOTE: If 12 is selected duplex is not possible.
5113 1 Selects the corresponding key for installed devices such as coin lock.
5118*
Disable Copying DFU
5120*
Clr-OP Count Remv [0=Yes / 1=Standby only / 2=No]
5120 1 Determines under which conditions the copy job settings are reset when the key
counter is removed. With 0, the settings are cleared if the counter is removed at the
end of a job or midway through a job. With 1, they are only cleared if the counter is
removed at the end of a job. With 2, they are not cleared at all, under either
condition. With duplex copies, the job settings are always preserved, regardless of
the setting of this SP mode.
5121*
Count Up Timing [0 = Feed In / 1 = Exit]
5121 1 Selects whether the key counter increments at time of paper feed-in or at time of
paper exit.
5127*
APS Mode [0 = Enabled / 1 = Disabled]
5127 1 Enables or disables the APS mode..
5162*
Application Switching Method [0 = Soft Key Set / 1 = Hard Key Set]
5162 1 Determines whether the application screen is switched with the hardware switch or
the software switch.
5302*
Set Time
[-1440 ∼ +1440 / 0 / 1 minute/step]
5302 2 Species the difference between your local time and GMT.
⇒
Rev. 06/2005