SERVICE PROGRAM MODE
B121 Series/B259 Series 5-42 SM
5307*
Summer Time
Summer Time On/Off 5307 1
Enables or disables the daylight saving time settings in SP5-307-3 and 4.
OFF = 0, ON = 1
Summer Time Start ( 5.1.18) 5307 3
Specifies the start of the daylight saving time.
Summer Time End ( 5.1.18) 5307 4
Specifies the end of the daylight saving time.
5404*
User Code Count Clear
5404 1 Initializes the user code counter.
5501*
PM Alarm Interval
PM Alarm Interval (Printout) [0 ~ 9999 / 0 / 0K copies/step] 5501 1
Specifies when the PM alarm occurs.
PM Alarm Original Count Alarm [0 = Off / 1 = On] 5501 2
Enables or disables the original count alarm.
5504* Jam Alarm
5504 1 Sets the alarm to sound for the specified jam level (document misfeeds are not
included).
[0~3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5505* Error Alarm [0 ~ 255 / 20 / 1 hundred sheets/step]
5505 1 Specifies the number of paper (in hundred) used as the error alarm level. The error
alarm starts if 5 SC codes (or more) are generated before the copier prints the
specified number of paper. When the copier has printed the specified number of
paper, the SC code counter (of this SP) is cleared to zero.
5507* Supply Alarm
5507 1 Paper Supply Alarm 0: Off, 1: On, DFU
5507 3 Toner Supply Alarm 0: Off, 1: On, DFU
5507 128 Interval :Others
5507 132 Interval :A3
5507 133 Interval :A4
5507 134 Interval :A5
5507 141 Interval :B4
5507 142 Interval :B5
5507 160 Interval :DLT
5507 164 Interval :LG
5507 166 Interval :LT
5507 172 Interval :HLT
[00250 ~ 10000 / 1000 / 1 Step] DFU