MFP EXPANSION
B121 Series/B259 Series 1-40 SM
1.12.4 SETTINGS
Step 10–MFP Settings and Time Settings
1. Turn the main switch on.
2. Start the SP mode.
3. Select SP5-801-001 and execute the initialization.
4. Turn the main switch off and on.
5. Start the SP mode.
6. Select SP5-302-002 and specify the time zone. For example, EST = -300, CST
= -360, MST = -420 or PST = -480.
7. Select SP5-307-001, 003, and 004 and specify the daylight-saving-time
settings. ( 5.1.18)
NOTE: 5.1.7. When installing to MFP Expansion, the BICU (Engine) NVRAM
settings are moved from SP5-801 to SP5-998-001. After adding the MFP
Expansion performing SP5-801-001 will not RAM CLEAR the BICU
settings.
Step 11–Fax Settings
1. Select fax SP1-101-016 and specify the system switch.
2. Select fax SP3-101-001 and specify the service station.