Loading...
ARDF
B379
TIMING CHARTS
SM 11 B379
2.5 TIMING CHARTS
2.5.1 SINGLE-SIDED ORIGINAL MODE (A3)
26.2mm (32.2-5-1mm)
50ms
5mm
JAM#1A
200ms
327.6mm
JAM#6
327.6mm
JAM#2, 3, 5
420mm
JAM#4
50ms
5mm
327.6mm
50ms
5mm
168.1mm
50ms
Feed Motor
Transport Motor
CW
TXD
RXD
MAX
READ
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ENABLE
DISABLE
DF Feed Clutch
DF Pick-up
Solenoid
Original Set
Sensor
Original Exit
Sensor
Registration
Sensor
FGATE
B379D510.WMF