SERVICE PROGRAM MODE
SM 5-23 B121 Series/B259 Series
Service
Tables
Dsply–Info Count
7991*
Displays the total operating time or the total number of operations. The time is
displayed in the following format: day:hour:minute:second.
Dsply–Info Count (Dsply-Timer Count) 7991 1
The total of the time when the main switch is kept on (excluding the time when the
safety switch is off [ 6.6.3]).
Dsply–Info Count (Dsply-APS Working) 7991 2
The total of the time when the APS is working.
Dsply-Info Count (Dsply-ID S Work) 7991 3
The total of the time when the ID sensor is working.
Dsply-Info Count (Dsply-Dev Counter) 7991 4
The total number of paper outputs.
Dsply-Info Count (Dsply-ID Er Count) 7991 5
The total number of ID-sensor errors.
7992*
Reset–Info Count
Reset–Info Count (Reset-Timer Count) 7992 1
Clears the counter of SP7-991-1.
Reset-Info Count (Reset-ID Er Count) 7992 5
Clears the counter of SP7-991-5.