ARDF
B379
TIMING CHARTS
SM 13 B379
2.5.3 DOUBLE-SIDED ORIGINAL MODE
Transport Motor
CW
TXD
RXD
MAX
READ
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ENABLE
DISABLE
DF Feed Clutch
DF Pick-up
Solenoid
Original Set
Sensor
Original Reverse
Sensor
Registration
Sensor
FGATE
Feed Motor
MAXCCW
CW
MAX
READ
OFF
ON
OFF
Original Exit
Sensor
ON
OFF
ON
OFF
Junction Gate
Solenoid
200ms
JAM#1A
50ms
5mm
200ms
JAM#7
50ms
32.8mm
5mm
50ms
200ms
5mm
50ms
50ms
JAM#7
200ms
JAM#7
50ms
32.8mm
5mm
50ms
200ms
168.1mm
50ms
50ms
JAM#7
50.7mm
JAM#6
36.2mm (32.5-5-1mm)
JAM#2, 3, 5
50.7mm
JAM#1B
JAM#2, 3, 5
26.2mm
JAM#6
50.7mm
JAM#1B
JAM#2, 3, 5
26.2mm
JAM#6
JAM#2, 5
60mm
JAM#2, 3, 5
26.2mm
JAM#1B
JAM#6
50.7mm
JAM#6 JAM#6
JAM#1B
JAM#2, 5
B379D512.WMF

Table of Contents