ERROR CODES
B620 12 SM
Code Meaning Suggested Cause/Action
2-51
The machine resets itself
because of a fatal
communication error
If this is frequent, update the ROM, or replace the
FCU.
4-01 Line current was cut
Check the line connector.
Check for line problems.
Replace the FCU.
4-10
Communication failed
because of an ID Code
mismatch (Closed Network)
or Tel. No./CSI mismatch
(Protection against Wrong
Connections)
Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
The machine at the other end may be defective.
5-00
Data construction not
possible
5-10 DCR timer expired
Replace the FCU.
5-20
Storage impossible because
of a lack of memory
5-21 Memory overflow
Temporary memory shortage.
Test the SAF memory.
Replace the FCU or optional EXMEM board
5-23
Print data error when
printing a substitute rx or
confidential rx message
Test the SAF memory.
Ask the other end to resend the message.
Replace the FCU.
5-25 SAF file access error
Replace the FCU.
6-00
G3 ECM - T1 time out
during reception of facsimile
data
6-01
G3 ECM - no V.21 signal
was received
6-02
G3 ECM - EOR was
received
Try adjusting the rx cable equalizer.
Replace the FCU.
6-04 G3 ECM - RTC not detected
Check the line connection.
Check connections from the NCU to the FCU.
Check for a bad line or defective remote terminal.
Replace the FCU.
6-05
G3 ECM - facsimile data
frame not received within 18
s of CFR, but there was no
line fail
Check the line connection.
Check for a bad line or defective remote terminal.
Replace the FCU.
Try adjusting the rx cable equalizer
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
6-06
G3 ECM - coding/decoding
error
Defective FCU.
The other terminal may be defective.
6-08
G3 ECM - PIP/PIN received
in reply to PPS.NULL
The other end pressed Stop during
communication.
The other terminal may be defective.
6-09 G3 ECM - ERR received
Check for a noisy line.
Adjust the tx levels of the communicating
machines.
See code 6-05.