Operation - Additional displays (optional equipment)
6 - 39
830 / 07.2012
Original operating instructions
Hydraulic oil pre-heater
(electrical)
(optional)
The hydraulic oil pre-heater (1) is attached to the hydraulic tank. The
warm-up period is significantly reduced by the hydraulic oil pre-heater.
To activate the hydraulic oil pre-heater, the socket (3) in the left-hand
storage space of the machine must be connected to the mains. The
socket (3) is fused via the fuse box (4).
Only the plug and not the cable for power supply to the socket is
supplied by SENNEBOGEN!
The cable must only be connected by a trained specialist!
Set the temperature using the regulator (2) on the thermostat (pre-setting:
40°C [104°F]).
The thermostat switches off once the operating temperature has been
reached.
Warning
Maintenance and repair work must only be carried out by trained
specialist personnel.
Note
To increase the effectiveness of the hydraulic oil preheating, retract all
hydraulic cylinders.