Operation - Work application
6 - 76
830 / 07.2012
Original operating instructions
Auxiliary limiting
extend stick
DANGER
Never change the limit shutdown (6) setting set at the factory!
Adjustment to the setting may be carried out only by SENNEBOGEN
Customer Service or an authorized SENNEBOGEN Service Partner!
With auxiliary limiting installation — set the stick as follows:
Note
The optional auxiliary limiting (5) cannot be bypassed.
5 Auxiliary limiting “Extend stick” (optional)
6 Limit shutdown “Extend stick” (optional)
6
5
1 Raise the stick carefully to just below the maximum height limit
(maintain safety clearance!).
2 Loosen the hexagonal nuts for auxiliary limiting (5).
3 Adjust the auxiliary limiting (5) until the sensors respond (LED
on sensor goes out).
4 Tighten the hexagonal nuts for auxiliary limiting (5).
5 Switch the Auxiliary limiting flip switch on at the control panel.
6 Check the setting carefully and repeat if necessary.

Table of Contents