EasyManua.ls Logo

sennebogen 830 E - Page 276

sennebogen 830 E
307 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation - Refueling the machine
6 - 90
830 / 07.2012
Original operating instructions
Note
Risk of cavitation!
Ensure that the maximum suction height of 3 m is not exceeded.
CAUTION
Ensure that the pump does not run dry (> 30 s).
Switch off the refueling pump with the switch (4) if necessary to prevent
damage.
Check the following points if the refueling pump does not start after
approx. 5 seconds:
7 Move the lever (3).
8 Switch on the refueling pump with switch (4).
The tank is filled automatically.
9 The pump switches off automatically as soon as the tank is full.
10 Remove the refueling hose from the external fuel tank and
stow securely.
11 Re-close the cover of the filler strainer.
12 Re-close the service access doors.
1 Is the battery charged?
2 Are all fuses in order?
3 Is the suction side free of leaks?
4 Is the maximum suction height 3 m or less?
4
3

Table of Contents