microScan3 Pro I/O
Scan cycle time 40 ms 0.39°
Devices with a max. protective field range of 9.0 m
Scan cycle time 40 ms 0.125°
Scan cycle time 50 ms 0.1°
Response time
Devices with a max. protec‐
t
ive field range of 4.0 m
≥ 70 ms, details: see "Response times", page 186
Devices with a max. protec‐
tive field range of 5.5 m
≥ 70 ms, details: see "Response times", page 186
Devices with a max. protec‐
t
ive field range of 9.0 m
≥ 90 ms, details: see "Response times", page 186
Scan cycle time
Devices with a max. protec‐
tive field range of 4.0 m
30 ms or 40 ms (configurable)
Devices with a max. protec‐
t
ive field range of 5.5 m
30 ms or 40 ms (configurable)
Devices with a max. protec‐
tive field range of 9.0 m
40 ms or 50 ms (configurable)
Generally necessary protective field supplement (TZ = tolerance zone of the safety laser
sc
anner)
Devices with a max. protec‐
tive field range of 4.0 m
65 mm
Devices with a max. protec‐
tive field range of 5.5 m
65 mm
Devices with a max. protec‐
t
ive field range of 9.0 m
100 mm
Additional supplement
Z
R
for reflection-based meas‐
urement errors
350 mm
Deviation from ideal flatness
of sc
an field at 5.5 m
3)
≤ ± 100 mm
Deviation from ideal flatness
of sc
an field at 9.0 m
4)
≤ ± 100 mm
Distance of mirror rotational
axis (zero point of x and y
axis) to rear side of device
56 mm
Distance between center
point of scan plane and top
edge of the housing
40 mm
Multiple sampling 2 … 16
1)
The collision protection field is available only for devices with the Pro performance package and a
ma
ximum protective field range of 9 m.
2)
Protective field resolution 60 mm only available for devices with max. protective field range of 9.0 m.
3)
Devices with a max. protective field range of 4.0 m and devices with max. protective field range of 5.5 m.
4)
Devices with a max. protective field range of 9.0 m.
Safety-related parameters
T
able 32: Safety-related parameters
microScan3 Pro I/O
Type Type 3 (IEC 61496)
13 TECHNICAL DATA
180
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice