S120 Combi Power Modules
4.9 Technical data
SINAMICS S120 Combi
110 Manual, 11/2017, 6SL3097-4AV00-0BP7
Table 4- 22 Technical data of the S120 Combi 4 axes Power Modules
10 kW / 24 A
/ 12 A / 12 A
/ 12 A
16 kW /
18 A / 9 A /
5 A / 5 A
16 kW /
24 A / 9 A /
9 A / 9 A
20 kW / 30 A /
12 A / 9 A /
9 A
Rated power (S1)
1)
Infeed power for S6 duty P
S6
(40%)
1)
1)
kW (P
n
)
kW (P
s6
)
max
10
13
16
21
16
21
20
26.5
Rated power (S1)
kW (P
n
)
10
16
16
20
Line voltage
Line frequency
V
AC
Hz
DC
3 AC 380 – 10% … 3 AC 480 + 10%
45 … 66
at 400 VAC
at 380 VAC / 480 VAC
at 400 V; for S6 duty I
S6
(40%)
A
AC
A
AC
A
AC
16.2
17 / 12.8
21.1
28
29 / 25
35.5
28
29 / 25
35.5
34
35 / 30
44
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
2)
max
A
ACrms
A
ACrms
A
Crms
Crms
20.4
32 at 4 kHz
19.2 at
8 kHz
15.3
24
20.4
32
25.5
40
at 540 V DC-link voltage
kW
11.7
8.7
11.7
14.4
0 … 0.7 x DC-link voltage
Rated current (I
n
)
Base load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
A
ACrms
A
ACrms
A
ACrms
10.8
16
7.7
12
7.7
12
10.3
16
at 540 V DC-link voltage
kW
5.8
4.3
4.3
5.8
Pulse frequency feedrate 1
V
ACrms
0 … 0.7 x DC-link voltage