S120 Combi Power Modules
4.9 Technical data
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
111
Rated current (I
n
)
Base load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
max
A
ACrms
A
ACrms
A
ACrms
ACrms
10.8
16
4.3
6.5
7.7
12
7.7
12
at 540 V DC-link voltage
kW
5.8
2.4
4.3
4.3
Pulse frequency feedrate 2
0 … 0.7 x DC-link voltage
Rated current (I
n
)
Base load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
A
ACrms
A
ACrms
A
ACrms
10.8
16
4.3
6.5
7.7
12
7.7
12
at 540 V DC-link voltage
kW
5.8
2.4
4.3
4.3
Pulse frequency feedrate 3
V
ACrms
0 … 0.7 x DC-link voltage
Output for expansion axis
DC
DC-link output current (I
n
DC
Max. electronics output current
for expansion
A
24Vmax
20
Electronics current consumption 24 VDC
Without external fan unit
A
1.6
1.6
1.6
1.6
(including losses from the electronics, see Power
loss tables (Page 113))
internal
external
The external 6SL3161-0EP00-0AA0 fan module
is taken into account for the specified losses –
also see Power loss calculation for partial load
W
W
W
770
115
655
492
87
405
607
100
507
733
113
620
Without derating
° C
45
45
45
45
V
DC
460 … 720
V
DC
820 ± 2%
See Section Line-side overcurrent protective devices