S120 Combi Power Modules
4.9 Technical data
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
111
4 axes Power Modules
6SL3111-
4VE21-0EA1
4VE21-6FA1
4VE21-6EA1
4VE22-0HA1
Output current
Rated current (I
n
)
Base load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
Peak current (I
max
)
A
ACrms
A
ACrms
A
ACrms
A
ACrms
12
10.8
16
36
5
4.3
6.5
10
9
7.7
12
18
9
7.7
12
18
Rated power
at 540 V DC-link voltage
at 600 V DC-link voltage
kW
kW
5.8
6.5
2.4
2.7
4.3
4.8
4.3
4.8
Pulse frequency feedrate 2
kHz
4
4
4
4
Output voltage
V
ACrms
0 … 0.7 x DC-link voltage
Feedrate 3
Output current
Rated current (I
n
)
Base load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
Peak current (I
max
)
A
ACrms
A
ACrms
A
ACrms
A
ACrms
12
10.8
16
36
5
4.3
6.5
10
9
7.7
12
18
9
7.7
12
18
Rated power
at 540 V DC-link voltage
at 600 V DC-link voltage
kW
kW
5.8
6.5
2.4
2.7
4.3
4.8
4.3
4.8
Pulse frequency feedrate 3
kHz
4
4
4
4
Output voltage
V
ACrms
0 … 0.7 x DC-link voltage
Output for expansion axis
DC-link voltage
V
DC
510 … 720
DC-link output current (I
n
)
A
DC
18.5
40
Max. electronics output current
for expansion
axis
A
24Vmax
20
General data
Electronics current consumption 24 VDC
Without external fan unit
With external fan unit
A
A
1.6
2.4
1.6
2.4
1.6
2.4
1.6
2.4
Total power loss
(including losses from the electronics, see Power
loss tables (Page 113))
internal
external
The external 6SL3161-0EP00-0AA0 fan module
is taken into account for the specified losses
also see Power loss calculation for partial load
operation (Page 302).
W
W
W
770
115
655
492
87
405
607
100
507
733
113
620
Max. ambient temperature
Without derating
With derating
° C
° C
45
55
45
55
45
55
45
55
DC-link voltage
V
DC
460 … 720
DC-link capacitance
μF
2520
1645
2115
2520
Overvoltage tripping
Undervoltage tripping
V
DC
V
DC
820 ± 2%
380 ± 2%
Circuit breaker/fuse
(IEC 60947 and UL)
See Section Line-side overcurrent protective devices
(Page 34)