Cabinet design and EMC   
12.5 Connection system 
  SINAMICS S120 Combi 
286  Manual, 11/2017, 6SL3097-4AV00-0BP7 
Comparison of MOTION-CONNECT power cables 
MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. The 
MOTION-CONNECT 800PLUS power cables fulfill all high mechanical requirements for the 
use in tow chains. They are resistant to cutting oils. 
Table 12- 8  Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS power cables  
VDE 
1)
 
cURus or UR/CSA 
UR-CSA File No. 
2)
 
Yes 
UL758-CSA-C22.2-N.210.2-M90 
Yes 
Yes 
UL758-CSA-C22.2-N.210.2-M90 
Yes 
0
/V in accordance with EN 50395 
Supply conductors 
600 V / 1000 V 
24 V (EN) 1000 V (UL/CSA) 
600 V / 1000 V 
24 V (EN) 1000 V (UL/CSA) 
Supply conductors 
4 kV 
4 kV 
Operating temperature at the surface 
Permanently installed 
-20 … +80 °C 
-20 … +80 °C 
Permanently installed 
50 N/mm
2 
2
50 N/mm
2 
2
Permanently installed 
5 x D
max
 
4 x D
max
 
  30 m/min  Up to 300 m/min 
2
2
  CFC/silicone-free  CFC/halogen/silicone-free 
IEC 60754-1 / DIN VDE 0472-815 
  EN 60811-2-1 
EN 60811-2-1 
  PVC  PUR, HD22.10 S2 
  The registration number is printed on the cable jacket. 
2)
  The file number is printed on the cable jacket.